12
XXV Pellet Stove
This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure. If the chimney condition
is questionable* you may want to install a liner as in
method #6.
*The chimney should be inspected and cleaned
before installing your stove. If you discover that the
chimney does not have a clay tile liner or has cracks or
aking of the tile liner you will need to install a stainless
steel liner within the chimney. In most cases the inside
diameter of this liner should be 4". Either exible or rigid
liner may be used for this purpose. Refer to Method 6.
Be sure to design the venting so that it can be easily
cleaned.
This method will allow single wall 6" ue pipe to come
off the top of the stove and go directly into a masonry
or class A chimney.
This method will be desirable for people who are
replacing a wood or coal stove and have an existing
chimney to use.