Ready
Ready
The Ready indicator is displayed at the end of the Charge Only process.
The LCD indicates:
l The charging is complete and the battery is ready for use (READY).
l The battery voltage after charge (12.2VDC). This reading can vary between 10.2VDC and 12.6VDC.
Analyze
Initial Charge
When a battery is in the charge/analyze pocket and the analyze dome switch has been pressed within 15 seconds of inserting
the battery, the analyze process is started. The first step of the analysis process is to charge the battery, which may take up to
three hours.
The LCD indicates a rounded off version of voltage and:
l The battery is charging, indicated by the word CHARGE on the screen.
l This is the first charge cycle in the analyze process, indicated by the number 1 on the screen.
l The battery is under analysis, indicated by the word ANALYZE on the screen.
l The battery voltage under charge is displayed (11.2VDC). The voltage can vary from 9.0VDC to 12.7VDC.
Discharge
The next step in the analysis is the automatic discharging of the battery pack. The discharge requires 1.5 to 4 hours.
The LCD indicates:
l The battery is discharging, indicated by the word DISCHARGE on the screen.
l This is the first (and only) discharge cycle, indicated by the number 1 on the screen.
l The battery is under analysis, indicated by the word ANALYZE on the screen.
l The battery capacity as measured during the discharge (1120mAh).
l The battery voltage under discharge (10.2 VDC). This can vary from 9.0 VDC to 12.7 VDC.
E-EQ-MX3XCHGROG-C-ARC [ 9 ] MX3X Battery Charger User Guide