A SERVICE OF

logo

Troubleshooting
Problem Cause Solution
LED is flashing RED
at any station.
The battery pack voltage has not
reached 10.6VDC within 90 minutes
and the charger has timed out.
Contact your LXE representative for battery pack
replacement options.
Solid YELLOW /
AMBER LED when
battery pack is
inserted in the charger.
The battery pack is too hot or too cold
to charge.
Remove battery pack from the charger and allow it to adjust
to room temperature.
Note: If the battery pack is left in the charger, it will
cool down or warm to a temperature upon which the
charger will begin the charge cycle. However,
depending on the temperature of the battery, it may
take 2-3 hours to adjust. The cool-down / warm-up of a
battery pack is much quicker if the battery is not in the
battery well.
YELLOW LED comes
on when battery pack
is in the CHARGING
cycle. The charge
cycle has been
suspended.
The battery pack has become too hot
or too cold to continue charging.
If this is the first time the battery pack has initiated a
temperature fault, remove the battery pack and allow it to
achieve room temperature. Then try to charge the battery
pack a second time. If the YELLOW LED comes on again,
the battery pack is defective, or the temperature of the
charger or battery pack is out of specification.
BAT. FAULT is
displayed in the LCD
screen.
(Charge/analyze
pocket)
A problem has occurred with the
Multi-Charger Plus or the battery
pack.
Note the Error code displayed. Unplug charger from outlet.
Remove any dirt or foreign objects from charger pocket.
Check the pocket for bent or broken pins. Contact your LXE
representative if the error code reoccurs.
Error Code Indicated Problem
E01 Power Supply Under-Voltage
E02 Battery Over-Voltage
E03 Discharge Fault
E04 Four Hour Timeout
E05 90 Minute Timeout
E06 Six Hour Timeout
E07 Analyze 10 Hour Timeout
E08 +VCHRG Not Present
E12 Battery Open Circuit
E-EQ-MX3XCHGROG-C-ARC [ 12 ] MX3X Battery Charger User Guide