A SERVICE OF

logo

Commander GP User Guide
Issue code: gpxu2
2-10 Getting Started
The following conditions now apply:
All the default values (including those of the
motor parameters) take effect
Macro 0 is enabled
If required, any other macro configuration can be
enabled.
Enabling Macro 1
Warning
Do not attempt to enable any
macro configuration when the
Drive is running.
Note
If the Drive is to be operated in Macro 1 or
5 and a braking resistor is to be used, now
set parameter 0.15 at FASt. Then follow
the instructions below.
The setting of parameter 0.15 must be
changed now because the function of this
parameter is changed when one of these
macro configurations is enabled.
1. Set parameter 0.00 at 2001.
2. Reset the Drive.
The configuration layers (see Chapter 1 Introduction)
are now as follows:
1. Appropriate default configuration for the
continent (EUR or USA)
2. Macro 1 Easy mode
Configuring the Drive for the motor
Warning
The values of the motor
parameters affect the
protection of the motor and
the safety of the system.
Caution
When entering values, make
sure they are relevant to the
motor that is to be used. The
default values in the Drive
should not be relied upon.
The motor parameters should
be set to within 10% of the
required values for the motor.
Failure to do this may result in
poor response.
It is essential that the correct
value is entered in parameter
0.46 Motor – rated current. This
affects the thermal protection
of the motor.
Keep a note of the values given
to the motor parameters, since
motor parameters are restored
to their default values when
the Drive is restored to a
default configuration (this
must be done if the Drive has
been used with Macro 2 to 7
enabled and a different macro
configuration is to be enabled)