12 Helix
GB
Control Panel
4.4 Control Displays
Refer to item 2 in section 4. The graphic below
applies to both the Component Pump (A) and
Component Pump (B).
The Control Displays increase the functionality of the applicable
Component Pump.
It consists of a display (1) and four function keys (2). The display
showsvariousmenuscreensthatallowtheusertocustomizeand
monitor sprayer operation using the function keys.
SET PSI 0
ACTUAL PSI 0
1
2
i
When both component pumps are turned ON, the
system will automatically link the two Component
Pumps after 10 seconds. This means the Component
Pump (A) control display will be controlled by the
Component Pump (B) control display. When the
component pumps are linked, the Component Pump
(A) control display keys are disabled and will only
be functional when the two Component Pumps are
unlinked (see “Status Screen”).
i
The pressure control knob overrides the Control
Display settings. Anytime the pressure control
knob is turned, the sprayer pressure will change
accordingly.
The function keys are numbered 1–4. Each key is labeled with an
additional function as well.
Pressing the #1 key scrolls through the available
menu screens or performs a function described
on the active menu screen.
#2/p
Pressing the #2 key performs a function
described on the active menu screen or increases
a value.
#3/q
Pressing the #3 key performs a function
described on the active menu screen or decrease
a value.
Pressing the #4 key selects the active menu
screen or performs a function described on the
active menu screen.
Menu Screens
Severalmenuscreensareavailablefortheusertocustomizeand
monitorsprayeroperation.TheyincludeMainScreen,Vis-Comp
(ViscosityCompensation)*,Status*AlarmRange*,AlarmStatus*,
TotalCycles*,JobCycles*,UnitSerial#,Timers,JobTimers,Service
Time,SecurityCode*,andPrime.
Screens noted with an asterisk (*) are screens that
apply to Component Pump (B) only. All other
screens apply to both (A) and (B) pumps.
4.3 Component Pump Pressure Control
Refer to item 2 in section 4. The following items
control the pressure of the individual Component
Pumps.
MAX
PSI
MIN
PSI
2
1
1 Pressure control knob Adjusts the pump pressure of the
applicable Component Pump when
unlinked. When Component pumps
are linked, the (B) pump pressure
control knob will control the
pressure of both pumps.
2 ComponentPumpON/
OFF switch
SwitchestheComponentPumpON
and OFF.
MAX
PSI
MIN
PSI
1
3
2
1 Minimum pressure setting
2 Blackzone–nopressuregeneration
3 Maximum pressure setting