A SERVICE OF

logo

Helix 5
GB
General Description
2. General Description
The Helix Plural Component System is a dual, high pressure airless
sprayer system that can be linked in order to spray multi-component
uids.
2.1 System Congurations
The Plural Component System is available in the following
conguration which is based upon the number of heating elements,
hose length, electrical phases and the required power cord (not
supplied). Refer to the chart below.
Model Voltage
(phase)
Amps Hose
Watts
System
Watts
# Heating
Elements
Heated
Hose
Max Flow
(gal/min)
Max Fluid
Pressure
Cord Specication
AWG (mm)
0138010 230V(1) 56 1775 13000 3 200’(61m) 2.2 2000 PSI 6 (13.3), 2 wire + ground
2.2 Electrical / Generator Requirements
i
The Helix System requires a 208-240V capacity.
Make sure the power source is rated to this
specication.
i
When working at altitudes above 2100m, check the
generator manufacturer’s specications for power
loss oset.
Attention
If powering the Helix system with a generator, make
sure the generator has ample power to run the
system. An inadequate generator will cause RPM
uctuations in the Component Pump motors during
usage and can cause damage.
Follow the steps below to determing if your generator is able to
supplysucientpowertotheHelixsystem.
1. Determine the Watt gures on the Component Pumps. This
can be found on the specication labels located underneath
the pumps near the uid section.
2. Add the wattage that is required by the Component Pumps
(that gure is 10,000 Watts).
3. Performthisequation:
Watts Component A + Watt Component B + 10,000 x 1.25 =
kVA(kilovolt/amperes)
4. Ifyourgenerator’skVAratingishigher than what was
determined in the equation above, the generator will be able
to power the system.
Ifyourgenerator’skVAratingislower than what was
determinedintheequationabove,thegeneratorWILLNOTbe
able to power the system. A larger generator is required.