Classe Audio CA-D200 Car Amplifier User Manual


 
21
event log Reserved for ampliers, this feature is a protection circuitry event log which can
only be accessed when the target amplier is in standby. e protection circuit
shuts down the amplier or channel if it overheats or if its output could damage
your speakers. e event log details the circumstances surrounding the amp
going into protection and should be referred to in situations that require the
intervention of your dealer or Classé customer support.
e log can report the following events interpreted as follows:
• +ve slow blo trip & -ve slow blo trip — e average current has
reached the safe operating limit.
• +ve fast blo trip & -ve fast blo trip — e peak current has
reached the safe operating limit.
• over temperature trip — e unit temperature has reached the
safe operating limit.
• DC Output trip
e DC output level has reached the safe
operating limit.
• Communication failure — ere has been a loss of
communicationbetweentheamp’ssystemmonitoringsensors.
• AC line trip — (Does not apply to CA-D200) e power supply
hasreachedthelimitsoftheamp’ssafeoperatingrange.
• Air intake lter — (Does not apply to CA-D200) e intake
lter is constricting airow and should be cleaned. is “event”
is also triggered after every 2,000 hours of operation, even if
the sensors do not yet detect constricted airow. e unit will
continue to operate with its standby LED ashing until the lter
is checked and the unit reset by pressing and holding the standby
button for 3 seconds.
Events are rare and generally occur due to issues that are external to the amp.
eyshouldbeinterpretedpositively.eampisdoingwhatit’sdesignedtodo.