Kenmore 153.33205 Car Satellite TV System User Manual


 
Minimum 3ft. (91 cm}
Minimum 3 ft. (91 era) within a
hMght of 15_. (4.6 m) above
meter/regulator assam bly
Minim,
12 in= (30 am)
from sides of
permanently
cUosed window
[] VENT TERMINAL
thatreay be open
below a window that from side ofwindow
Minimum 12 in. (30 era) above may be open that may be open
window or door thatmay be open
(_ AIR SUPPLY INLET [] AREA WHERE TERMINAL IS NOT PERMITTED
suppUy inUatintobuilding
or combustion air iMet
to another appUianee
1. Permitted only if veranda, porch, deck or balcony is fully opened on a minimum of two sides beneath the floor
2. A vent shall not terminate above a sidawaUk or paved driveway that is located between two single family dwelUings and sePces bMh dwelhgs,
FIGURE 23.
This unit can vent through 2", 3" or 4" nonmetallic pipe and fittings.
The vent pipe installationcan be started from either the blower discharge
or the termination wall. Keep in mind the total vent system (pipe and
elbows) when installing the vent system, see VENTING AND
INSTALLATION AND MAXIMUM VENT LENGTHS, page 17.
MORTAR OR WALL PLATE
SILICONE {OPTIONAL}
CAULK / PVC VENT
/
TERMINAL WITH
MESH PROTECTUVE
SCREEN INSI[:)E
FROM
WATER
HEATER
PVC
COUPLING
FIGURE24.
The vent terminal should be kept as dose as possible to the outside
wall, but you need to allow at least 1.5" (3.8 cm) of pipe past the wall,
for the wall flange and vent terminal to mount on the pipe.
Before the vent terminal is installed, caulk (not supplied) around the pipe
on the exterior wall and install the optional wal! flange. The flange can be
held to the outside wall by placing some of the caulking on the back of the
flange. The wall flange is supplied for decorative purposes only and is
not a requirement for the vent termination (if not needed by the installer).
VERTICAL VENT THROUGH ROOF
This unit is approved for venting through the roof with the type vent
terminal that is included with the unit. A proper flashing or "BOOT"
should be used to seal the pipe where it exits the roof.
The total vent system should not exceed that which is specified, see
VENTINGAND INSTALLATION, page 17.
All of the pipe should be secured as per the instructions in the instructions
inthe VENTING AND INSTALLATION, page 17.
VERTICAL VENT TERMINATION RESTRICTIONS
1. Minimum of twelve !2" (30.5 cm) above the roof or twelve 12"
(30.5 cm) above the anticipated snow level Provide proper support
for all pipe protruding through the roof.
'VENT
TERMINAL
*ALL PUPE PROTRUDRNG THROUGH THE ROOF
SHOULD BE PROPERLY SUPPORTED.
RGURE 25.
2. 4' (! .2 m) from or 1' (0.3 m) above any gable, dormer, or other roof
structure with access to interior of building (i.e.=vent, window etc.).
3. 3' (0.9 m) above any forced air inlet located within 10' (3.0 m).