Kompernass KH 2391 Car Stereo System User Manual


 
21 GB/IE
Disconnection
Remove the USB plug of the USB audio storage
medium completely from the USB port do.
Or
Press the SD / MMC in the SD and MMC port dn
in order to unlock it.
Remove the SD / MMC from the SD and MMC
port dn.
LRemote Control
Tip!
Familiarise yourself with use of the similar buttons
on the remote control (see Fig. F). Please see the
layout of the control panel 1 for the functions.
Ensure that the front edge of the remote control is
pointing in the direction of the sensor 3of the re-
mote control 1.
Please note that the AF function only works with
ther
AF
button 8on the control panel 1.
Please also note the modified procedure for:
Adjusting the Volume
Increase the volume by pressing the
VOL+
button gt.
Reduce the volume by pressing the
VOL-
button hm.
Inserting the Battery
Press the unlock button ipand remove the
battery holder iofrom the battery compart-
ment in(see Fig. G).
Insert a lithium battery of type CR2025, 3 V DC
into the battery holder ioin such a way that
the side marked with a “+” is facing upwards.
Then push the battery holder iointo the battery
compartment inuntil it distinctly locks into place.
L Troubleshooting
E Fault e Cause E Correction
E The device cannot be switched on and / or
[ERROR] appears in the display window 9.
The connections of the 12 V DC power supply
are faulty.
E Check that the wiring of the device is correct
(see the section on „Connecting to the Vehicle‘s
12 V DC Power Supply“). Then press the RESET
button
d
rwith the tip of the ballpoint pen.
Or
The 10 A f lflat blade fuse in the flat blade
fuse socket euis broken.
E Replace the broken flat blade fuse with a new
10 A flat blade fuse. Then press the RESET
button
d
rwith the tip of the ballpoint pen.
Or
A 15 A fuse of the fuse holder of the 12 V DC
power supply is broken.
E Replace the broken fuse with a new 15 A fuse.
Then press the RESET button
d
rwith the tip of
the ballpoint pen. If the fuse is broken again,
check that the wiring is correct.
Or
The device is broken.
E Please contact the service centre for your
country (see guarantee card).
E The device cannot be operated.
The control panel 1is wrongly connected.
E Ensure that the control panel 1is correctly
connected (see the section on attaching the
control panel).
Or
The battery of the remote control is flat.
E Replace the used battery with a new lithium
battery of type CR2025, 3 V DC.
Or
The sensors 3of the control panel 1and / or
remote control may be dirty.
E Clean the sensor 3of the control panel 1or
the remote control if necessary.
Or
The device is broken.
E Please contact the service centre for your
country (see guarantee card).
E The stored stations do not remain stored if
the control panel is removed or the engine
turned off.
The connections for 12 V constant current fn and
12 volt ignition current fphave been mixed up
Operation / Remote Control / Troubleshooting
KH2391_Content_UK.indd 21 05.09.2006 14:49:18 Uhr