SETTINGS OF CAMERA CONTROL AND STATUS REGISTER
CSR F100000Ch Image Size
Set the size of the area when cutting one part of the screen by the partial scan function.
Minimum Unit for DFW-SX900 Minimum Unit for DFW-X700
Set the size of the area using the width and height of the rectangular area composed of the minimum units in the above
figure.
This area is 1/4 the width and 1/2 the height
of the whole screen.
<When DFW-SX900>
Command = 0iii0jjjh iii: Width of area jjj: Height of area
Width (x) i i i
---------------------------------------------------------
1/4 of whole screen 140h (320)
1/2 of whole screen 280h (640)
3/4 of whole screen 3C0h (960)
Whole screen 500h (1,280)
Height (y) j j j
--------------------------------------------------------
1/4 of whole screen 0F0h (240)
1/2 of whole screen 1E0h (480)
3/4 of whole screen 2D0h (720)
Whole screen 3C0h (960)
<When DFW-X700>
Command = 0iii0jjjh iii: Width of area jjj: Height of area
Width (x) i i i
---------------------------------------------------------
1/2 of whole screen 200h (512)
Whole screen 400h (1,024)
Height (y) j j j
--------------------------------------------------------
1/4 of whole screen 0C0h (192)
1/2 of whole screen 180h (384)
3/4 of whole screen 240h (576)
Whole screen 300h (768)
1/2
y
0 1/2 x