A SERVICE OF

logo

37
DFW-SX900
DFW-X700
COMMAND SENDING PROCEDURE UNTIL IMAGES ARE DISPLAYED
Address
F1000144h
Action
Write
Data
02800000h
Packet size = 640
Address
F1000138h
F100013Ch
Action
Read
Read
Data
00096000h
00000000h
Lower 32 bits
Upper 32 bits
Address
F1000140h
Action
Read
Data
02800140h
Unit = 320, Max = 640
e) Specify the packet size.
This camera is designed so that Unit is the minimum Frame Rate and Max is the maximum Frame Rate.
Set a value which is the integral multiple of the Unit and at the same time does not exceed the maximum value for the
packet size.
The range of isochronous transmission is determined by the packet size.
NOTE
: When ImagePosition/ImageSize/ColorCodingID are set at step d), the camera
recalculates and reflects the contents of CSR F1000140h PacketParaInq register.
If set so that the packet size is changed, be sure to perform this procedure.
f) Acquire the TotalBytes.
Image data size sent by the camera. For application softwares, secure a buffer of this size and prepare to receive data
transmitted isochronously.
Address
F0F00614H
Action
Write
Data
00000000H
ISO Enable OFF
Address
F0F00604h
F0F00608h
F0F0060Ch
F0F00614h
Action
Write
Write
Write
Write
Data
00000000H
E0000000H
12000000H
80000000H
Video Mode = 0
Video Format = 7
ISO ch = 1, Speed = 400M bps
ISO Enable ON
To stop the video, set the ISO Enable bit to 0.
(6) Video transmission start command (Format7)
When the following values are set for Status and Control registers for camera, the camera starts video transmission.
As there is no concept for the frame rate for Format7, the specification of CSR F0F00600h FrameRate will be ineffective.