A SERVICE OF

logo

© Titan Tool Inc. All rights reserved. 25
Outlet Accessories
930 Outlet Manifold Filter Assembly with Check
Valve
930-514 930-515 930-516
Item
Part # Description Qty.
Qty.. Qty.
1 930-937 Filter cap assembly .......1 .............1.............1
2 930-020 Spring ............................1 .............1.............1
3 930-005 Filter element,
5 M, w/ball .....................1
930-006 Filter element,
50 M, w/ball ...................................1
930-007 Filter element,
100 M, w/ball ................................................1
4 920-006 Gasket, PTFE (thick).....1 .............1.............1
5 920-070 Gasket, PTFE (thin) ......1 .............1.............1
6 891-193 O-ring, PTFE.................1 .............1.............1
7 180-909 Seat, tungsten carbide ..1 .............1.............1
8 930-920 Filter body......................1 .............1.............1
9 193-331 Hex nipple......................*..............* .............*
10 812-003 Hex nipple......................* ..............* .............*
11 227-033 Pipe plug........................*..............* .............*
12 191-449 Hex nipple......................* ..............* .............*
*Order installation kit P/N 930-101.
Filter Service Kit (P/N 930-050)
Item Part # Description Quantity
2 930-020 Spring ...................................................1
4 920-006 Gasket, PTFE.......................................1
5 920-070 Gasket, PTFE.......................................1
6 891-193 O-Ring, PTFE.......................................1
Specifications
Maximum Working Pressure............5000 psi (345 bar)
Filter Area.........................................18 In
2
(116 cm
2
)
Outlet Ports......................................(1) 1/4" NPT(F) for bleed
valve
(1) 3/8" NPT(F) with 1/4
NPSM(M) hose connection
(1) 3/8" NPT(F) plugged for
additional gun hookup.
Wetted Parts ....................................Carbon steel with electroless
nickel and cadmium plating,
stainless steel, tungsten
carbide, PTFE
1
2
3
4
5
6
7
8
9
10
11
11
12
Operation
The 930 Series Outlet Manifold Filter has a built in spring actuated
check valve. It uses a replaceable filter element with a stainless
steel check ball permanently trapped inside the element. The
element is available in the following screen sizes:
Part #
Mesh Typical Applications
930-005 5 High viscosity materials
930-006 50* Conventional materials
930-007 100 Low viscosity materials
The filter cap has a long stem that acts as a spring guide and
controls ball travel within the filter element. The filter body has a
replaceable tungsten carbide seat which is secured by a PTFE o-
ring.
The incorporation of this spring loaded check valve into the filter
manifold greatly reduces hydraulic shock at stroke changeover
and reduces opportunity for hydraulic stalls. Always use the 930
Series Filter Element / Check Ball in this PowrLiner system. Do
not use 920 Series filter elements. Do not run the system
without a 930 Series filter element/check ball. When using heavy
high viscosity materials, use the 5-mesh filter element/check ball.
Cleaning
Clean filter regularly. Dirty or clogged filters can greatly reduce
filtering ability and cause a number of system problems including
poor spray patterns, clogged spray tips, etc.
To clean the filter, shutoff system and relieve all system pressure,
see the Pressure Relief Procedure in the Safety Warnings
section of this manual
Remove filter cap with spring guide (1) and spring (2). Pull filter
element with check ball (3) straight out of filter body (8).
Thoroughly clean inside filter body (8), filter element with check
ball (3), and filter cap with spring guide (1) with appropriate
solvent. Use care in handling parts as dirt, debris, scratches, or
nicks may prevent o-rings or gaskets from sealing.
The 930 Series Filter Elements filter from the inside out. Be
certain to clean the screen element thoroughly on the inside.
Soak in solvent to loosen hardened paint. etc. or replace.
Service
1. Inspect ball trapped inside filter element (3). If ball has
pressure cuts or scratches, replace filter element.
2. If ball is cut, remove PTFE o-ring (6) with an o-ring pick and
remove tungsten carbide seat (7). Check carbide seat for
nicks or grooves. If seat is nicked or grooved, replace.
3. Removal of the PTFE o-ring (6) for seat (7) inspection will
damage the o-ring and require replacement.
4. Remove the spring (2) from the filter cap (1). Measure the
length of the spring, uncompressed. If it measures less than
3/4" from end to end, replace. Push spring back onto spring
guide until it "snaps" in place.
5. Inspect the PTFE gaskets (4, 5) and o-ring for deformity,
nicks, cuts, etc. Replace as required.
Reassembly
After inspecting and cleaning all parts, reassemble the filter assembly.
1. Place tungsten carbide seat (7) in filter body, using care to
place the beveled side up.
2. Place PTFE o-ring (6) in groove on the outer diameter of the
tungsten carbide seat (7).
3. Place filter element/check ball (3) back in filter body (8).
4. Place spring (2) back onto spring guide in filter cap (1).
Push spring onto guide rod until it "snaps" in place.
5. Place thin PTFE gasket (5) onto step at top of the filter body (8).
6. Place thick PTFE gasket (4) onto top of the gasket (5).
7. Tighten filter cap (1) onto filter body (8). This will engage o-
ring (6) against tungsten carbide seat (7).
NOTE: The top and bottom of the filter element/check
ball are identical.
NOTE: The PTFE o-ring (6) and PTFE gaskets (4, 5) are
packaged in the Filter Service Kit (P/N 930-050).
NOTE: Inspect all parts thoroughly.