Carson SC-411-RD-1014 Car Amplifier User Manual


 
Page 6 of 12 Installation and Operating Instructions SC-411RD-10
7/30/12 CP5094C
OPTION SETTINGS
Enter/Exit Program Mode
Turn unit on with POWER input.
Enter the program mode by pressing and holding OUT/DIM, S1 and S2 for 3 seconds.
The unit will beep 3 times and the backlighting will begin flashing to indicate that the unit is in program mode. It
will continue to flash until program mode is exited by pressing and holding OUT/DIM for 3 seconds, saving the
settings—the unit will emit a long beep.
NOTE: Press and hold the left directional indicator button for 3 seconds to reset to factory default.
Program Mode Sections
S1 - S6 Switch Operation
1. With lever switch in off position, Lever numbers 1, 2 and 3 will be lit and each of the auxiliary switch’s
current operation program status is indicated on the face of the unit by flashing the RED lights on the push
buttons. See the table below for switch status definition.
2. Change each switch’s operation by momentarily pushing the switch.
3. Light ON - Push On / Push Off with video output trigger active (default)
4. Light OFF - Push On / Push Off with video trigger output deactivated.
5. Light flashing continuously - Momentary.
6. Light flashing with double pulse - Timed Momentary (Gun Lock Timer) for duration of 10 seconds.
7. Light flashing with triple pulse - Timed Momentary (Gun Lock Timer) for duration of 20 seconds.
8. The options with cycle through and repeat with each push of the button.
Note: The Timed Momentary operation, typically used as a Gun Lock Timer, can be used with any Auxiliary
control switch but any switch so set will not be available to the Lever switch association.
Lever / S1 - S6 Switch Association
Set the lever switch to desired number position to program. The number corresponding to that position will light
up continuously.
Press the desired auxiliary switch to turn on or off the light and tie it to the lever switch position.
NOTE: The Timed Momentary (Gun Lock Timer) programmed switches may not be added to combination.
Press the OUT/DIM button momentarily to move into next section, or OUT/DIM for 3 seconds to save & exit.
Press
OUT/DIM
Lever Display Programming
0
+ +
S1-S6 Switch Operation
1
or or
Lever / S1-S6 Switch Assoc
2
blinking
Option Set 1
3
blinking
Option Set 2
50
+ blinking
Second Tone Control
4
blinking
Option Set 3
Lever Switch = OFF Shows + + (all on)
Press S1 S2 S3 S4 S5 S6
0 On On On On On On On/Off with Video Output
(Default)
1 Off Off Off Off Off Off On/Off without Video Output
2 1-Flash 1-Flash 1-Flash 1-Flash 1-Flash 1-Flash Momentary
3 2-Flash 2-Flash 2-Flash 2-Flash 2-Flash 2-Flash Momentary with 10-sec Hold
40 3-Flash 3-Flash 3-Flash 3-Flash 3-Flash 3-Flash Momentary with 20-sec Hold
Lever Switch = 1 or 2 or 3 Shows or or
Press S1 S2 S3 S4 S5 S6
0 Off Off Off Off Off Off No Association (Default)
1 On On On On On On Associated with 1 or 2 or 3
S1
S2
S3
S4
S5
S6
OFF
1
2
3
PA VOL
WARNING: WEAR HEARING PROT ECTION REF. OSHA 1910.95
YELP
WAIL
STBY
PHSR
CYCLE
RADIO
CARSON
SC
SCSC
SC
-
--
-
411
411411
411
Elite
Force
OUT/DIM
MANUAL
HORN