Dayton Operating Instructions and Parts Manual
13
Model 4E769B
Version B - For Reduction G016.J
®
4E769B
Description Part No.
10' Rubber Hose with Brass Fitting LPA1020
U.L. listed.
15' Rubber Hose with Brass Fitting LPA1030
U.L. listed.
Propane Gas Regulator LPA2110
U.L. listed.
Hose/Regulator Assembly LPA3090
U.L. listed.
Fuel Gas Connector LPA4020
Connects regulator to all standard
propane tanks. U.L. and A.G.A. listed.
Tank Stabilizer LPA5000
Accessories
Troubleshooting Chart (Continued)
Symptom Possible Cause(s) Corrective Action
Heater shuts down while running 1. High surrounding air temperature
causing thermal limit device to shut
down heater
2. Restricted air flow
3. Damaged fan
4. Excessive dust or debris in surround-
ing area
1. This can happen when running
heater in temperatures above 85°F.
Run heater in cooler temperatures
2. Check heater inlet and outlet.
Remove any obstructions
3. Replace fan. See Fan, page 8
Use only in areas
free of high dust
content.
4. Clean heater. See Maintenance, page 7