Dayton Operating Instructions and Parts Manual
3
Model 4E769B
Version B - For Reduction G016.J
®
Specifications
ELECTRICAL SPECIFICATIONS
Electrical
Input Amperage
120 Volt/60Hertz 2
General Safety Information
(Continued)
Manifold Hot Air Output Supply Pressure Temperature Range
Pressure (CFM Approx) Ignition To Regulator For Operating Heater Motor
10.8" WC 175 Manual 10 psi Minimum (for) -20° F to 85° F* 2735 RPM
Piezo purposes of input
adjustment) Tank Pressure
or 200 psi Maximum
GENERAL SPECIFICATIONS (Cont.)
(*) When running heater in temperatures above 85° F, high internal temperatures may cause thermal limit device to shut down
heater.Minimum ambient operating temperature: -20°F (-28°C).
Output Fuel Size Regulator Weight
Rating BTU/Hr Fuel Consumption L x W x H (Inches) Outlet Pressure (pounds)
35,000 Only Propane Vapor .38 Gallons/Hour 18.5 x 7.7 x 12.8 11" WC 14.5 (Heater)
1.6 Pounds/Hour 16 (Shipping)
GENERAL SPECIFICATIONS
• The electrical connections and
grounding of the heater shall follow
the National Electric Code, ANSI/
NFPA 70.
• Use only the electrical voltage and
frequency specified on model plate.
• Electrical grounding instructions —
This appliance is equipped with a
three-prong (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle.
• Use only a three-prong, grounded
extension cord.