Dynacord DPA 4120 Car Amplifier User Manual


 
28
DPA 4120: For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing
4 ampere type, labeled "T4A" (see also paragraph 11.1).
DPA 4140: For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing
8 ampere type, labeled "T8A" (see also paragraph 11.2).
If the appliance is correctly connected and mains is present the green STANDBY indicator (4) will light. To remotely
start the amplifier when it is being operated on the mains, it is necessary to interconnect the contacts 3 - POWER
REMOTE and 2 - GROUND STANDBY on the pin terminal strip REMOTE CONTROL (16) (see also paragraph 5.6).
The main power switch POWER (9) on the rear of the appliance is meant for service and maintenance purposes. This
allows bridging the mains switching relay, which provides the possibility to operate the amplifier without remote start.
Note The main power switch POWER (9) on the appliance's rear is only meant for maintenance. Remotely
switching off the device is not possible when the POWER switch is engaged.
Both amplifiers, the DPA 4120 and the DPA 4140, employ power-on switching delays of approximately 3 sec. After
this time, the green READY indicator lights and the READY fault message relay picks up when no error is being
detected (see also paragraph 6.2).
3.2 Battery operation 24V DC
The amplifiers, DPA 4120 and DPA 4140, use the mains or alternatively an external 24V battery as power source.
Switching to battery is performed via integrated relays.
The battery has to be connected on the rear of the amplifiers (20) using insulated 6.3x0.8 mm AMP flat plug
connectors. The amplifiers are protected against polarity-mismatch. Each, the positive and negative conductors are
internally protected by fuses, located on the printed board assembly 85270 (DPA 4120) respectively 85268 (DPA
4140) (see also paragraph 11, figure 10 and 11).
The cable used for battery connection has to be at least 1.5 mm
2
in diameter (DPA 4120) respectively 2.5 mm
2
(DPA
4140). Using these diameters, the cable length for the one way distance should not exceed 4.0 m (max. voltage drop
<1V).
Caution The DPA 4120 and DPA 4140 are to be operated only using ungrounded batteries or batteries with
grounded negative pole. Operation with grounded positive pole is not permissible.
4. INPUT
The electronically balanced INPUT (14) providing a sensitivity of 775mV = 0dBu is meant for the connection of control
amplifiers. In case it is intended to supply several power amplifiers with identical input signals, these signals can be
taken from the THRU connector (15) (see also figure 1 and 2).
The input is prepared to be retrofitted with a input transformer. In case a floating input is needed, it is necessary to
install the optional extension NRS 90208 (see also paragraph 8.3).
On the general input module NRS 90225 the input level is set with the level control (13). For the remote control
module NRS 90222 the input level is determined by the setting of the internal electronic level control of the
PROMATRIX manager DPM 4000 (please also refer to the PROMATRIX handbook).