I - 112
SM830082
1
2
3
4
5
1. Specifications
Indoor model: TH4242 / Outdoor model: CH4242
● Cooling
● Heating
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 V 208 V 230 V 208 V 230 V 208 V 230 V 208 V
Rating conditions
A 0.8 0.7 1.8 1.8 18.0 18.8 20.6 21.3
kW 0.18 0.15 0.36 0.34 3.76 3.71 4.3 4.2
Full load conditions
A 0.8 0.7 1.8 1.8 21.0 22.6 23.6 25.1
kW 0.18 0.15 0.36 0.34 4.49 4.49 5.03 4.98
Starting amperes A 1 1 2 2 131 131 133.8 133.7
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 V 208 V 230 V 208 V 230 V 208 V 230 V 208 V
Rating conditions
A 0.8 0.7 1.8 1.8 19.1 20.0 21.7 22.5
kW 0.18 0.15 0.36 0.34 3.91 3.86 4.45 4.35
Full load conditions
A 0.8 0.7 1.8 1.8 21.2 23.6 23.8 26.1
kW 0.18 0.15 0.36 0.34 4.52 4.67 5.06 5.16
Starting amperes A 1 1 2 2 131 131 133.8 133.7
Cooling:
Rating Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 95 °F DB
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 115 °F DB
Heating:
Rating Conditions : Indoor Air Temperature 70 °F DB / 60 °F WB
Outdoor Air Temperature 47 °F DB / 43 °F WB
Full Load Conditions : Indoor Air Temperature 80 °F DB / — °F WB
Outdoor Air Temperature 45 °F DB / 35 °F WB