I - 61
SM830082
1
2
3
4
5
1. Specifications
Indoor Unit: TH4242 Outdoor Unit: CH4242
• 230V / 1 phase / 60Hz
RATING CAPACITY : 42,000 BTU/h AIR FLOW RATE: 900 CFM
EVAPORATOR CONDENSER
ENT.TEMP.°F(°C) AMBIENT TEMP °F(°C)
WB DB 75 85 95 105 115
(23.9) (29.4) (35.0) (40.6) (46.1)
TC 42,550 40,490 38,140 35,490 32,550
CI 3.03 3.3 3.6 4.02 4.44
72(22.2) SHC 29,360 28,200 26,920 25,510 24,000
59 76(24.4) SHC 32,530 31,380 30,090 28,690 27,170
(15.0) 80(26.7) SHC 35,850 34,690 33,410 32,000 30,490
84(28.9) SHC 39,020 37,860 36,580 35,170 32,550
88(31.1) SHC 42,190 40,490 38,140 35,490 32,550
TC 44,140 42,170 40,070 37,670 35,070
CI 3.06 3.35 3.65 4.08 4.5
72(22.2) SHC 25,230 24,220 23,160 21,990 20,740
63 76(24.4) SHC 28,400 27,390 26,340 25,160 23,920
(17.2) 80(26.7) SHC 31,720 30,710 29,650 28,470 27,230
84(28.9) SHC 34,890 33,880 32,820 31,650 30,400
88(31.1) SHC 38,060 37,050 36,000 34,820 33,580
TC 45,820 44,020 # 42,000 39,770 37,340
CI 3.08 3.38 3.69 4.12 4.55
72(22.2) SHC 21,080 20,240 19,310 18,300 17,230
67 76(24.4) SHC 24,260 23,410 22,480 21,470 20,410
(19.4) 80(26.7) SHC 27,570 26,730 25,790 24,790 23,720
84(28.9) SHC 30,740 29,900 28,970 27,960 26,890
88(31.1) SHC 33,920 33,070 32,140 31,130 30,070
TC 48,260 46,580 44,770 42,800 40,610
CI 3.11 3.41 3.75 4.18 4.62
72(22.2) SHC 17,020 16,300 15,540 14,720 13,840
71 76(24.4) SHC 20,190 19,470 18,710 17,890 17,010
(21.7) 80(26.7) SHC 23,510 22,790 22,020 21,210 20,320
84(28.9) SHC 26,680 25,960 25,200 24,380 23,500
88(31.1) SHC 29,850 29,130 28,370 27,550 26,670
TC 49,220 47,630 45,950 44,020 41,960
CI 3.17 3.47 3.8 4.24 4.69
75 76(24.4) SHC 15,640 15,030 14,400 13,680 12,930
(23.9) 80(26.7) SHC 18,960 18,350 17,710 16,990 16,240
84(28.9) SHC 22,130 21,520 20,880 20,170 19,410
88(31.1) SHC 25,300 24,690 24,060 23,340 22,590
TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW)
Rating conditions are
M.R.= 14.78 USpints/h
:Outdoor Ambient Temp.95° FDB
:Indoor Unit Entering Air Temp.80° FDB/67° FWB