36
DSR Series
74.01 : TIMER-2 DATA
When the DEVICE is required the TIMER-2 DATA by the “61.0C : CURRENT TIME
SENSE” command, the TIMER-2 DATA (UNRESETTABLE COUNTER) will be added to the
DATA-1 through DATA-4.
At that time, the DF/NDF mode of TIMER-2 is set to the BIT-6 of DATA-1.
For the data format, refer to “24.31 : CUE UP WITH DATA”.
74.04 : LTC TIME DATA
When the DEVICE is required the LTC TIME DATA by the “61.0C : CURRENT TIMER
SENSE” command, the LTC TIME DATA will be added to the DATA-1 through DATA-4.
For the data format, refer to “24.31 : CUE UP WITH DATA”.
78.04 : LTC TIME & UB DATA
When the DEVICE is required the LTC TIME DATA and USER’s BIT DATA by the “61.0C :
CURRENT TIME SENSE” command, the LTC TIME DATA will be added to the DATA-1
through DATA-4 and the LTC USER’S BIT DATA will be added to the DATA-5 through
DATA-8.
For the data format, refer to “24.31 : CUE UP WITH DATA” and “4X.05 : USER’S BIT
PRESET”.
74.05 : LTC UB DATA
The DEVICE is required the LTC USER’s BIT DATA by the “61.0C : CURRENT
TIMER SENSE” command, the LTC USER’S BIT DATA will be added to the DATA-1
through DATA-4.
For the data format, refer to “4X.05 : USER’S BIT PRESET”.
74.06 : VITC TIME DATA
The DEVICE is required the VITC TIME DATA by the “61.0C : CURRENT TIME SENSE”
command, the VITC TIME DATA will be added to the DATA-1 through DATA-4.
For the data format, refer to “24.31 : CUE UP WITH DATA”.
78.06 : VITC TIME & UB DATA
The DEVICE is required the VITC TIME DATA and the USER’S BIT DATA by the “61.0C :
CURRENT TIME SENSE” command, the VITC TIME DATA will be added to the DATA-1
through DATA-4 and the USER’S BIT DATA will be added to the DATA-5 through DATA-8.
For the data format, refer to “24.31 : CUE UP WITH DATA” and “44.05 : U-BIT PRESET”.
74.07 : VITC UB DATA
The DEVICE is required the VITC USER’S BIT DATA by the “61.0C : CURRENT TIME
SENSE” command, the VITC USER’S BIT DATA will be added to the DATA-1 through
DATA-4.
For the data format, refer to “44.05 : U-BIT PRESET”.
74.14 : LTC INTERPOLATED TIME DATA
When the DEVICE is required the LTC TIME DATA by the “61.0C : CURRENT TIME
SENSE” command and it interpolates with CTL or it had not read exactly, the LTC TIME
DATA will be added to the DATA-1 through DATA-4.
For the data format, refer to “24.31 : CUE UP WITH DATA”.