Specifications
37
Sync: TTL level, 2.2 kilohms, polarity
free (H/V separate and composite
sync)
Plug & Play function: corresponds to
DDC2B
DVI input connector
DVI-D (1)
TMDS (Single link)
Output
Video output connectors
BNC type (4)
Loop-through, with 75 ohms automatic
terminal function
4-pin mini DIN (1)
Loop-through, with 75 ohms automatic
terminal function
External Sync output connector
BNC type (1)
Loop-through, with 75 ohms automatic
terminal function
General
Power AC100 to 240 V, 50/60 Hz,
1.2 A ~ 0.6 A
Power consumption
Maximum: approx. 100 W (when two
BKM-255DV are attached)
Maximum: approx. 92 W (when no
input adaptor is attached)
Peak inrush current
(1) Power ON, current probe method:
60 A (240 V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1: 52
A (230 V)
Operating conditions
Temperature0 °C to 40 °C (32 °F to 104 °F)
Recommended temperature
20 °C to 30 °C (68 °F to 86 °F)
Humidity 30 % to 85 % (no condensation)
Pressure 700 hPa to 1060 hPa
Storage and transport conditions
Temperature–10 °C to 40 °C (14 °F to 104 °F)
Humidity 0 % to 90 % (no condensation)
Pressure 700 hPa to 1060 hPa
Accessories supplied
AC power cord (1)
AC plug holder (2)
Instructions for Use (1)
CD-ROM (1)
Warranty Card (1)
Using the CD-ROM Manual (1)
Quick Reference (1)
When You First Use the Monitor (1)
Sales Companies Guide (1)
Optional accessories
SDI 4:2:2 input adaptor
BKM-220D
HD/D1-SDI input adaptor
BKM-243HS
DV input adaptor
BKM-255DV
NTSC/PAL input adaptor
BKM-227W
Analog Component input adaptor
BKM-229X
Monitor stand
SU-560
Medical Specifications
Protection against electric shock:
Class I
Protection against harmful ingress of water:
Ordinary
Degree of safety in the presence of flammable
anesthetics mixture with oxygen:
Not suitable for use in the presence of flammable
anesthetics mixture with oxygen
Mode of operation:
Continuous
Design and specifications are subject to change without
notice.