Chapter 5. RS-232 Commands
51
Save/Load Profile Commands
The formulas for Save/Load Profile commands are as follows:
1. Command + Profile + Number + Address + Number + Control + [Enter]
For example, to save the current connection configuration to profile 12 on
device 01, type the following:
profile f 12 a01 save [Enter]
2. Command + Profile + Number + Address + Number + Control + [Enter]
For example, to load profile 12 on device 01, type the following:
profile f 12 a01 load [Enter]
The following tables show the possible values for commands:
Profile Description
fProfile
Command Description
profile Save / Load profile
Profile
Number
Description
yy 00-31 (default is 00)
Address Description
a Device address
Device
Number
Description
zz 00-15 (default is 00)
* All devices
Control Description
save Save the current connection
configuration
load Load a saved profile