BMC Software, Inc., Confidential and Proprietary Information
Managing the BEA WebLogic Environment 4-9
Administering Probe
Summary: Perform these steps to turn on or off annotations for Probe parameters
and to turn on or off event generation for Probe timing data.
Annotations apply to the AvgPingTime and AvgConnTime parameters
and include information about the time each data point was collected and
the value of the timing data parameter. Event generation sends timing
information to the PATROL Event Manager (PEM) when the parameter
status is in WARNING or ALARM. Use PEM to manage event data.
To use the Probe Administration dialog box:
Step 1
Right-click the BEAWLS_PROBE application icon.
Step 2 From the KM commands menu, choose Administration.
The Probe Administration dialog box is displayed.
Step 3 Click checkboxes to turn individual features on or off. A check indicates
that the feature is turned on. Additional information about each of the
features is provided in Table 4-1.
Step 4 Click OK.
select this box to
generate events when
AvgPingTime is in
WARNING or ALARM
select this box to
generate events when
AvgConnTime is in
WARNING or ALARM