Display shows any of the following:
DD Microprocessor RAM error in
Control Box.
Turn Power off at power source.
Wait 5 seconds. Turn power back
on. If Err 211 is displayed again,
then replace CB mother PC board.
DD Microproceeor RAM Error in object
board other than Control Box (Such
as feed head)
Cycle power as in Err 211. If Err
212 is still displayed, then replace
PC board in the object with fault.
The object with the fault should be
solid red on its status LED.
+)** Appears on right display of CB mod-
ule that contains the status Led
Dashes indicate that the encoder
does not control anything including
on/off output control.
Observe all Safety Guidelines detailed throughout this manual
Error Codes for the Power Wave
®
455: Code 10555 and below
%AF7For any Err # listed below write down the error number for refference and try cycling power to see if the