Technical Notes
A-6
Phaser 300X Color Printer
Serial port
The printer’s serial port provides an RS-232 interface connection to PCs and
other hosts. The printer’s serial port has these built-in default settings.
Variable (factory default, Switch 7, down)
Baud rate — 9600
Flagging — Software (XON/XOFF)
Parity — None
Stop bits — 1
Data bits — 8
Check parity — False
Protocol — Normal
When Switch 7 on the printer’s rear panel is in the down position,
you can change the default setting. To change the serial port’s
settings, you can use the PostScript Level 2 setdevparams
command. Refer to the Phaser 300X Drivers and Utilities Printing
Reference for details.
Fixed (Switch 7, up)
Baud rate — 1200
Flagging — Software (XON/XOFF)
Parity — Space
Stop bits — 1
Data bits — 7
Check parity — False
Protocol — Normal