© Titan Tool Inc. All rights reserved. 7
Cleanup
Do not use gasoline to clean the sprayer.
Special cleanup instructions for use with flammable
solvents:
• Always ush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting ushed solvents in a one gallon metal container,
place it into an empty ve gallon container, then ush solvents.
• Area must be free of ammable vapors.
• Follow all cleanup instructions.
IMPORTANT: The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits material to
build up, seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or any
other solvent to clean the sprayer, hose, or gun. Static
electricity buildup may result in a fire or explosion in
the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the Operation
section of this manual.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent (refer to recommendations of the material
manufacturer). An example of the appropriate solvent is
water for latex paint.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to the
PRIME position.
NOTE: Hold the return hose in the waste
container when moving the PRIME/
SPRAY valve to PRIME in case the
sprayer is pressurized.
On/O
Clean
Min.
PSI
(Bar)
Max. PSI
(Bar)
S
p
r
a
y
L
a
t
e
x
P
a
i
n
t
s
&
H
e
a
v
i
e
r
C
o
a
t
i
n
g
s
S
p
r
a
y
C
l
e
a
r
s
,
L
a
c
q
u
e
r
s
&
E
n
a
m
e
l
s
6. Turn the unit on and set the pressure to Turbo
PulseClean by turning the pressure control
knob to its CLEAN position in the red zone.
7. Allow the solvent to circulate through the unit
and ush the paint out of the return hose into
the metal waste container.
8. Turn the unit o by moving the pressure
control knob to the OFF position in the black zone.
9. Move the PRIME/SPRAY valve up to its SPRAY
position.
10. Turn the unit on and set the pressure to Turbo
PulseClean by turning the pressure control knob
to its CLEAN position in the red zone.
Ground the gun by holding it against
the edge of the metal container
while flushing. Failure to do so may
lead to a static electric discharge,
which may cause a fire.
11. Trigger the gun into the metal waste container until the paint
is ushed out of the hose and solvent is coming out of the gun.
12. Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
mineral sprits through the entire system.
13. Follow the “Pressure Relief Procedure” found in the Operation
section of this manual.
14. Unplug the sprayer and store in a clean, dry area.
IMPORTANT: Do not store the unit under pressure.
Cleaning the Spray Tip
1. Flush the gun with solvent immediately after the work is
completed.
2. Oil the sliding pins to prevent them
from seizing up.
Should the spray tip become clogged, reverse
the spray tip with the lever and pull the trigger.
Once the obstruction comes out of the spray
tip, release the trigger, reverse the spray tip
back to the spray pattern setting, and resume
spraying.
Do not attempt to clean the tip with your finger.
Do not use a needle or other sharp pointed instrument
to clean the tip. The hard tungsten carbide is brittle
and can be chipped.
Maintenance
Before proceeding, follow the “Pressure Relief
Procedure” outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver 3/8” Hex Wrench
Needle Nose Pliers 5/16” Hex Wrench
Adjustable Wrench 1/4” Hex Wrench
Rubber Mallet 3/16” Hex Wrench
Flat-blade Screwdriver 5/32” Hex Wrench
1. Before repairing any part of the sprayer, read the instructions
carefully, including all warnings.
IMPORTANT: Never pull on a wire to disconnect it. Pulling on a
wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
sure that the problem is corrected. If the sprayer does not
operate properly, review the repair procedure to determine if
everything was done correctly. Refer to the Troubleshooting
section to help identify other possible problems.
3. Make sure that the service area is well ventilated in case
solvents are used during cleaning. Always wear protective
eyewear while servicing. Additional protective equipment
may be required depending on the type of cleaning solvent.
Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your TITAN
Airless Sprayer, call TITAN:
Technical Service (U.S.) ...................................... 1-800-526-5362
Fax ................................................................. 1-800-528-4826