If the touchscreen is not responding to touch, check your serial or USB connection by doing the following:
Serial Connection - Run the comdump diagnostic utility to determine if the touchscreen, the serial
touch controller, the computer's serial COM port and the associated cabling are connected and
functioning properly. Download the latest version of comdump.exe (7K) from the Elo Web site
Driver and Files Download page. You should save the file where it can be accessed easily - either
to a floppy or to the root of your hard drive. Comdump is a DOS application, so if you are running
one of the Windows operating systems you must either boot to a DOS boot diskette or disable the
driver so you can access the COM port from a command prompt.
USB Connection - If the Human Interface Device (HID) is not listed in Device Manager after a USB
touchmonitor is connected, check to determine if a file named mouhid.sys is in the \windows (or
winnt) \system32\drivers folder.
The file will be missing if a USB mouse has never been connected to the system.
If the file is not there, connect a USB mouse to the system or copy mouhid.sys from another
system.
Once mouhid.sys is in the proper location, remove and reinstall the touch drivers.
If you have determined that the HID files are missing or corrupted ("Error installing mouse" when
installing the HID drivers, and also a yellow "!" in Device Manager under Mouse), check that all of
the following files are present in the \\winnt\system32\drivers folder:
Hidusb.sys
Hidclass.sys
Hidparse.sys
Mouhid.sys
If all the files are there, try replacing them with the same files from a known good system. It is
suggested that you save the original files in a backup directory.
The touch can not be held longer than 10 seconds. IntelliTouch controllers have a built-in two minute
untouch time-out. By default, the 4.20 Universal driver generates an untouch after 10 seconds of
constant touch. The untouch time-out can be changed by modifying a registry key. This time-out will
override any registry time-out value if the registry value exceeds 120 seconds (120000 milliseconds).
To change the time-out time:
1. Run regedit or regedt32 (click Start > Run, enter regedit).
2. Drill down to HKEY_LOCAL_MACHINE > SYSTEM > CurrentControlSet > Enum.
a. For serial controllers: SERENUM > ELOSERIAL > ******* > Device Parameters.
b. For USB controllers: HID > VID_04e7 > ******** > ***************** > Device Parameters.
NOTE: The "******" entries are id numbers used by the Windows operating system.
3. Double-click the UntouchTimeOut key. The Edit DWORD Value dialog box opens.
4. Click the Decimal radio button. Value displays in decimal (default: 10000).
5. Enter the delay time in milliseconds, 60000 is 60 seconds.
18 Appendix A Troubleshooting ENWW