Table A-1. NI-DSP Analysis Library Error Codes (Continued)
Error
Number
Error Name Description
-21218 WinDutyCyclesErr The window duty cycle value must be between 0.0 and 100.0.
-21219 dtGTZero dt must be greater than zero.
-21220 DutyCycleErr The duty cycle must meet: 0 duty cycle 100.
-21221 CyclesErr The number of cycles must be greater than zero and less than or
equal to the number of samples.
-21223 UpperGELower The upper value must be greater than or equal to the lower value.
-21225 IntervalNumErr The number of intervals must be greater than zero.
-21226 MixedSignErr The sign of y in Ax=y values must be all positive or negative.
-21227 SizeGTOrder The array size must be greater than the order.
-21228 OrderGTZero The order must be greater than zero.
-21229 ConvSizeErr The number of elements of convolved arrays should be greater
than zero.
-21233 NyquistErr The cutoff frequency, fc, must meet: 0 fc fs/2.
-21234 Nyquist2Err The following conditions must be met:
0 f_low f_high fs/2.
-21235 RippleGTZero The ripple amplitude must be greater than zero.
-21236 AttenGTZero The attenuation must be greater than zero.
-21237 WidthGTZero The width must be greater than zero.
-21242 SizeGTZero The size of the input sequence must be greater than zero.
-21243 NullVectorErr The input vector is null. The unit vector does not exist.
-21245 AttenGTRipple The attenuation must be greater than the ripple amplitude.
-21246 StepSizeErr The step-size parameter µ must meet: 0 µ 0.1.
-21248 LeakErr The leakage coefficient, Leak, must meet: 0 Leak µ.
-21249 FilterDesignErr The filter cannot be designed with the specified input parameters.
-21250 LenGEOne The number of coefficients must be greater than or equal to one.
-21251 RankErr The rank of the filter must meet: 1 (2 rank +1) size.
-21297 NotPowerOfTwo The size of the input array must be a valid power of two:
size = 2
m
, 0 < m < 14.
-21301 MEM_HRDWARE_ERR The onboard hardware diagnostic software found a memory
hardware error. Running functions on the board is unreliable.
-21302 ZERO_ALLOCATION There are no allocated buffers on the DSP board.
-21303 TooBigAnOffset The indexing requested falls outside of the buffer into which
indexing is requested.
-21304 HandleNotFound The DSP Handle specified is not found on this board: it has
either been freed or never allocated.
-21305 TooManyAllocs The Memory Look Up Table is full: no more allocations allowed
before freeing up some DSP handles (maximum allowed = 128).
-21306 PtrNotFound The DSP address pointer could not be found to free the buffer.
-21307 ParamSizeErr One of the parameters does not have enough space allocated for
it on the board.