National Instruments 320571-01 Car Stereo System User Manual


 
Appendix A Error Codes
© National Instruments Corporation A-3 NI-DSP SRM for LabVIEW for Windows
Table A-1. NI-DSP Analysis Library Error Codes (Continued)
Error
Number
Error Name Description
-21308 TransferSizeErr The size of requested block transfer does not have enough space
allocated for it on the board.
-21309 NotDSPHandle The DSP Handle specified is not valid for this board:
it has either been freed or never allocated.
-21310 HandleSlotErr The DSP Handle used does not belong to the same board on
which the function request is made.
-21311 HandleAllocErr Failed to allocate a handle in the interface code.
-21312 TimeOutErr The Kernel did not respond or finish function execution in the
selected timeout.
-21313 COFF_FilePathErr Could not find the DSP Library file in the directory set by the
DAQCONF utility.
-21314 CoffHdrErr The file you are attempting to load to the DSP board is not
created using the WE DSP32C tools (not an acceptable
COFF file).
-21315 CoffSectErr Found an unimplemented section flag in the COFF file.
-21317 AddrSpaceErr The COFF file you are trying to load is linked with a memory
map that exceeds the maximum memory space allowed by the
WE DSP32C chip (2
24
).
-21318 NoBrdRespToTransfer The DSP board on which you are trying to load the COFF file is
not responding to the transfer of the file. Check if there is a
board in the slot desired and verify with the DAQCONF utility.
-21324 FNC_ERR The function ID specified does not correspond to a function that
is part of the DSP Library currently running on the board.
-21325 GROUP_ERR The function ID specified does not belong to any group that is
part of the DSP Library currently running on the board.
-21331 NotFindFunctionInDLL An error occurs when loading dsp.dll library in CIN.
-21332 LoadDLLLibErr An error occurs when loading a function in dsp.dll in CIN.
-21333 ErrInGetFunctionHandle An error occurs when calling the
GetIndirectFunctionHandle function in CIN.
-21334 InvalidBytesSelect bytes/element selector can only select between 4 bytes(0) and 2
bytes(1).
-21336 AllocArrayFailed Failed to allocate a LabVIEW array.
-21337 InvalidArrayType The array type can only be 32-bit floating point data(0), 16-bit
long integer data(1) or 32-bit short integer data(2).
-21338 PathnameTooLong The path name should be less than 256 characters.
-21339 InvalidCopyType The entire/partial copy selector can only select between entire
copy (0) and partial copy(1).
-21340 CopyNumGTZero The number of data to copy should be greater than zero.
-21341 OffsetGEZero The offset should be greater than or equal to zero.
-21342 IndexSizeGTZero The size of the New DSP Handle Cluster should be greater than
zero.
(continues)