4.7 Fans
The fans mounted in the VORTEX operate permanently, but as long as the temperature remains below 40 °C they run at their slowest speed and can hardly be heard.
The highest detected temperature from either channel controls the speed of the fans: above 40 °C the speed is increased until it reaches its maximum value.
4.8 Filter Cleaning
A removable lter system is provided on the air intakes to the cooling system. If the lter becomes clogged, the unit will not cool as efciently as it should and may
produce output levels that are lower than normal due to high heat sink temperatures.
To clean, gently slide the whole plastic lter assembly to the left and release from the front panel. Carefully unclip the outer moulding to reveal the lter. Clean the lter
with a mild dishwashing detergent and warm water. Once dry, insert the lter back into the cradle and cover with the surround moulding. Slide the whole assembly to
the right to secure onto the front panel.
Spare lter assembly’s may be ordered from your dealer.
VORTEX Filter Assembly
1 Clip Apertures
2 Injection Moulded Cradle
3 Foam Filter
4 Injection Moulded Surround
5 Injection Moulded CAMCO Badge
3