CAMCO USER MANUAL
VORTEX POWER AMP SERIES
P.29
8.0 MEASURMENTS
2m
300m
5m
10m
20m
50m
100m
200m
20 20k50 100 200 500 1k 2k 5k 10k
-120
-20
-110
-100
-90
-80
-70
-60
-50
-40
-30
20 10k50 100 200 500 1k 2k 5k
-120
-20
-110
-100
-90
-80
-70
-60
-50
-40
-30
100u 6200u 500u 1m 2m 5m 10m 20m 50m 100m200m 500m 1 2
Figure 7.5
Output impedance vs. frequency @ 1 Amp RMS injected current. (Ch1, Ch2)
equivalent 11 mOhm + 2.1uH (Measurements of a typical performance)
Figure 7.6
THD+N @ 1 kHz, 4 Ohm load vs. input voltage (Ch1, Ch2)
(Measurements of a typical performance)
Figure 7.8
THD+N vs. frequency (BW 22 kHz), 3 dB below clip, 4 ohms (Ch1, Ch2)
(Measurements of a typical performance)
0
1000
200
400
600
800
20 20k
50
100 200 500
1k
2k
5k 10k
Figure 7.7
VORTEX 6 damping factor into 8 Ohm
equation: damping factor= loaded impedance / amplier output impedance
(Measurements of a typical performance)
Hz
Hz
Hz
Vrms
dB
dB Ohm
Damping factor