Extron electronic DTP HD DA8 4K 230/330 Car Amplifier User Manual


 
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 13
X1!
= TMDS output format
0 = Auto (default), pass through if HDMI sink, force
DVI format if DVI sink
1 = DVI RGB 444
2 = HDMI RGB “Full”
3 = HDMI RGB “Limited”
4 = HDMI YUV 444 “Limited”
5 = HDMI YUV 444 “Full”
6 = HDMI YUV 422 “Limited”
7 = HDMI YUV 422 “Full”
X1@
= HDCP output mode
0 = Encrypt as required by input
(Continuous trials for HDMI sinks, attempt for 10
seconds on DVI sinks,then fail)
1 = Always encrypt
(Continuous trials for HDMI sinks, attempt for 10
seconds on DVI sinks,then fail)
2 = Encrypt as required by input
(Continuous trials for HDMI sinks and DVI sinks)
3 = Always encrypt
(Continuous trials for HDMI sinks and DVI sinks)
X1#
= DTP/HDBaseT switch position
0 = DTP mode
1 = HDBaseT mode
X1$
= Verbose mode
0 = Clear/none (default for telnet)
1 = Verbose mode (default for RS-232 and USB)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
X1%
= Set date/time MM/DD/YY-HH:MM:SS
Example: Fri, 21 Jun 2002 10:54:00
X1^
= IP address
xxx.xxx.xxx.xxx
(192.168.254.254 = default)
X1&
= MAC address
00-05-A6-xx-xx-xx
X1*
= Subnet mask
xxx.xxx.xxx.xxx (255.255.0.0 = default)
X1(
= Password 12 digits and alphanumeric characters for user or
admin passwords.
NOTE: / \ | * and space are invalid characters.
X5&
= Port number
01 = Remote RS-232/RS-422 port
02 = unused
03-10 = UARTs 1 through 8
X5*
= Baud rate Default = 9600
Port 1 is fixed at 9600
X5(
= Parity Odd, Even, None (default), Mark, Space (only the first
letter is required)
X6)
= Data bits
7-8
(8 = default)
X6!
= Stop bits
1, 2
(1 = default)
X6$
= Port timeout intervals
1-65000
(1 = 10 seconds; default = 30 - 300 seconds = 5
minutes, in 10-second increments)
X6%
= Start point for UART ports
1999 = default
X6^
= Video mute
0 = Video mute disabled
1 = Video mute
2 = Video and sync mute