Garmin PAV80 Car Stereo System User Manual


 
PS Engineering
PAV80
Installation and Operator’s Manual
200-800-0101 Appendix E Rev. 5 Feb. 2004
Appendix E RTCA DO160D/EUROCAE ED-14D Environmental
Qualification Form
Part Number: 050-800-(-xxx)
Manufacturer: PS Engineering Incorporated 9800 Martel Road Lenoir City TN 37772
Conditions Section Conducted Tests
Temperature and Altitude
Low Temperature
High Temperature
In-flight Loss of Cooling
Altitude
Decompression
Overpressure
4.0
4.5.1
4.5.2
4.5.4
4.6.1
4.6.2
4.6.3
Equipment tested to CAT B1
-55° C Storage, -20°C Low Operating
+85°C Storage, +50°C High Operating
Not Applicable, no cooling required
25,000’ unpressurized
Not Applicable
Not Applicable
Temperature variation 5.2 Equipment tested to Category C
Humidity 6.0 Equipment tested to Category A
Shock 7.0 Equipment tested to Operational test only
Operational 7.2
Crash Safety 7.3
Equipment tested Category B
Vibration 8.0 Equipment tested to Category S
Explosion 9.0 Category X, not tested
Waterproofness 10.0 Category X, not tested
Fluids Susceptibility 11.0 Category X, not tested
Sand and Dust 12.0 Category X, not tested
Fungus 13.0 Category X, not tested
Salt Spray 14.0 Category X, not tested
Magnetic Effect 15.0 Equipment tested to Category Z
Power input 16.0 Equipment tested to Category B
Voltage Spike 17.0 Equipment tested to Category B
Audio Frequency Susceptibil-
ity
18.0 Equipment tested to Category B
Induced Frequency Suscepti-
bility
19.0 Category X, not tested
Radio Frequency Susceptibil-
ity
20.0 Category X, not tested
Radio Frequency Emission 21.0 Equipment tested to Category H
Lightning Induced Transient
Susceptibility
22.0 Category X not tested
Lightning Direct Effects 23.0 Category X not tested
Icing 24.0 Category X, not tested
Electrostatic Discharge 25.0 Category X, not tested
Other Tests Passed FM Emissions testing in accordance
with CFR 47, Part 15.109.