List of trouble log
Note: “nnn” of toggle article number is a generation frequency of the error.
Type
Test key
(Remote commander)
Toggle article
number
Content
Rebooting emergence
(Rebooting emergence
factor)
Test key2 (R)
2Annn
It was not possible to communicate with MTK ve seconds more continu-
ously
2Bnnn Compulsion power off demand was received from MTK
2Cnnn
Only MTK reset it
(Distination, model and region for are the disagreements)
2Dnnn Fails in the start of MTK
2Ennn Fails in the switch of the input mode of MTK
2Fnnn Input mode of MTK changed without permission
2Gnnn
Reacts to the key noti cation no though the communication with MTK is
alive
Serial communications
(MTK communication
error factor)
Test key3 (t)
3Annn It was not possible to communicate with MTK with 48ms
3Bnnn A non-standard packet length was received (Excluding 16 bytes)
3Cnnn Checksum NG
3Dnnn Type of the communication header is NG
3Ennn PEQ data reading operation (8032tDVDLIB) terminated abnormally
3Fnnn PEQ data writing operation (DVDLIBt8032) terminated abnormally
MTK power control
(Power ON/OFF error
factor)
Test key2 (r)
4Annn Fails in AC ON Initial
4Bnnn Fails in power on of MTK
4Cnnn Initialization response of CDM is abnormal
4Dnnn CDM mechanism error noti cation is received
4Ennn Input mode is NG MTK is started
4Fnnn MTK input mode switch at time fails usually
4Gnnn Fails in power off of MTK
4Hnnn Fails in power off of CDM