43
DSR Series
DATA No.8
DATA No.8/BIT-6 : LOST LOCK
BIT-6 will be set to “1” when the capstan or drum servo is locked over 10 second, and then the
servo is unlocked in the PLAY, REC or EDIT mode.
When the DEVICE receives the “40.2D : LOST LOCK RESET” command, BIT-6 will be
reset.
DATA No.8/BIT-4 : END OF TAPE
BIT-4 will be set to “1” when the DEVICE detects BEGIN or END of the cassette tape.
DATA No.8/BIT-0 : REC INHIBIT
BIT-0 will be set to “1” when the REC INHIBIT plug on the cassette is set.
For DSR-60/60P, this bit will always be set to “1”.
DATA No.9
DATA No.9/BIT-7 : FUNCTION ABORT
BIT-7 will be set to “1” when the event which is defined by the “4X.C4 : DEFINE EVENT”
command, is not executed normally.
DATA No.10
DATA No.10/BIT-5 : Δ t REC/PLAY EXECUTE
BIT-5 will be set to “1” when the device goes into the Δ t REC/PLAY mode.
DATA No.10/BIT-3 : Δ t READY
BIT-3 will be set to “1” when the device is in the Δ t REC/PLAY PRESET mode and ready to
go into the Δ t REC/PLAY mode.
DATA No.10/BIT-2 : VARIABLE REC/PLAY
This bit is set to “1” when the DEVICE receives the “43.3F : Δ t REC/PLAY PRESET”
command and goes into the Δ t REC/PLAY PRESET mode.
DATA No.12
DATA No.12/BIT-3 : DA4
DATA No.12/BIT-2 : DA3
DATA No.12/BIT-1 : DA2
DATA No.12/BIT-0 : DA1
The respective bits will be set to “1” in accordance with the contents of the data which has
been added to the command, when the DEVICE receives the “4X.30 : EDIT PRESET”
command.
Refer to “4X.30 : EDIT PRESET”.