TANDBERG TT1280 Car Satellite TV System User Manual


 
Operating the Equipment Remotely
Page 4-4 Reference Guide: TT128x High Definition Professional Receiver/Decoder
ST.RE.E10141.5
Table 4.2: Configuring the Serial Remote Port and Activating Remote Protocol
Step Action Result
1. Go to menu 7.1. Displays ‘OPERATING MODE’.
2. Press Edit. Displays ‘FRONT PANEL’.
3.
Press the down pushbutton and select
‘SERIAL REMOTE’.
The settings should be set to match the external control host.
4. Press Save. The unit is ready for Remote Control.
Once the communication parameters are entered correctly, set the system
into remote mode for the external computer to gain control of the unit:
Step Action Result
1. Go to menu 7.1.2. Displays ‘SERIAL REMOTE PROTOCOL’.
2. Press Edit. Toggle between RS-232 Alteia or RS-485 Alteia.
3.
Chose between RS-232 Alteia or RS-485
Alteia.
The settings should be set to match the external control host.
4. Press Save. The unit is ready for Remote Control.
4.1.5 Configuring the Unit For Remote Control Over-air
Overview
For the unit to be controlled via over-air control (OAC), the control mode
of the IRD needs to be set to Director NCP.
Table 4.3: Activating Director NCP Remote Control
Step Action Result
1. Go to menu 7.1. Displays ‘OPERATING MODE’.
2. Press Edit. Displays ‘FRONT PANEL’.
3.
Press the down pushbutton and select
‘DIRECTOR NCP’.
The settings should be set to match the external control host.
4. Press Save. The unit is ready for OAC.
OAC Lockout
Once the unit is in OAC control mode, it is possible for the remote control
operator to issue a local lockout command to the Receiver. This will
effectively deny the local user access to configuring the unit.
However, if a situation occurs whereby the local user needs to regain
control over the unit, without a local lockout relinquish command being
sent from the OAC control PC, a four digit Personal Identification Number
(PIN) may be entered through the keypad.
CAUTION…
TANDBERG Television Customer Services Help Desk will not be able to provide you with the Local
lockout PIN, as it is uniquely created at the time of the lockout.
The user creates the PIN at lockout time. To obtain the PIN, please consult
the person responsible for the administration of the unit.