PERIODIC MAINTENANCE 2-29
Periodic Maintenance Procedures
Final Drive
Variable Differential Control Lever Play Inspection
•
Pull the variable differential control lever [A] towards the
handlebar grip [B] with a spring scale until it reads 30 N
(3 kgf, 7 lb) of force.
○
The differential control in the front final gear case must be
locked, then the clearance [C] between the control lever
and grip should be 20 mm (0.8 in.).
If the clearance is not the specified length, adjust the ca-
ble.
Differential Control Lever Lock Position Length
Standard: 20 mm (0.8 in.)
Variable Differential Control Lever Play Adjustment
•
Remove:
Handlebar Cover Screws [A]
•
Remove:
Handlebar Cover Screws [A]
Handlebar Cover Front [B]
•
Loosen the locknut [A] of the differential control cable.
•
Turn the adjuster [B] until the cable has proper amount of
play.
•