amp info Available for amplifi ers only, this screen displays the data provided by the
heatsink and AC Module temperature sensors.
NOTE:  is feature is only accessible when the target amplifi er is on.
event log Reserved for amplifi ers, this feature is a protection circuitry event log which can
only be accessed when the target amplifi er is in standby.  e protection circuit
shuts down the amplifi er or channel if it overheats or if its output could damage
your speakers.  e event log details the circumstances surrounding the amp
going into protection and should be referred to in situations that require the
intervention of your dealer or Classé customer support.
e log can report the following events interpreted as follows:
+ve slow blo trip & -ve slow blo trip —  e average current has reached
the safe operating limit.
+ve fast blo trip & -ve fast blo trip —  e peak current has reached the
safe operating limit.
over temperature trip —  e unit temperature has reached the safe
operating limit.
DC protection trip —  e DC output level has reached the safe operating limit.
Communication failure —  ere has been a loss of communication
between the amp’s system monitoring sensors.
AC line trip —  e power supply has reached the limits of the amp’s safe
operating range.
ese events are rare and generally occur due to issues that are external to the
amp.  ey should be interpreted positively.  e amp is doing what it’s designed
to do.