4. DOOR LOCKS
Negative Lock Output / Positive Unlock Output (GREEN)
Negative Unlock Output / Positive Lock Output (BLUE)
Negative Second Door Unlock Output (BLUE/GREEN)
Positive Switching and Positive Switching with 2-step unlock feature:
All Door Lock and Unlock: Locate the lock / unlock wire at the vehicle’s lock / unlock switch.
Verification: These wires will register positive voltage when the Lock and Unlock switches are activated.
Driver’s Door Unlock: Locate the unlock motor wire directly from the actuator inside the driver’s door.
Verification: This wire will rest at ground and register positive voltage when the driver’s door is unlocked.
Connect the GREEN and BLUE or BLUE/GREEN wires shown in diagram 8 below.
Note: When adding the 2 step unlock feature the BLUE/GREEN 2nd door unlock wire will be used to unlock all
vehicle doors on the second press of unlock. Two additional SPDT relays (not supplied) (Code Alarm part
HDRLY) are required. Connect the relays as shown in diagram 9 to unlock the driver’s door on the first
press of unlock.
Lock
Unlock
Door Lock Switch
Vehicle Door Lock
Control Relays
BLUE (+) Lock Output
GREEN (+) Unlock Output
30
87
87a
86
85
To Unlock Side Of
Driver's Door Actuator
Fused +12 Volt
Battery Source
From Keyless Entry
Module Or Door
Lock/Unlock Relays
CUT
X
30
87
87a
86
85
BLUE/RED Second
Door Unlock Trigger
From Control Module
Fused +12 Volt
Battery Source
Chassis Ground
Diagram 9
BLUE/GREEN