Physical Considerations
2-4
Evaluation Module Layout
2.3 Area 200—Dual Device SOIC
Area 200 uses 2xx reference designators, and is compatible with dual op
amps, with or without shutdown, packaged as an 8-pin (without shutdown) or
14-pin (with shutdown) SOIC. This package is designated by a D suffix in TI
part numbers, as in TxxxxCD.
When using the nonshutdown version of the device, ensure that the IC is
aligned at the top of the IC pad array—the last six PCB pads (three on each
side—pins 5, 6, 7, 8, 9, and 10) will not be used.
Figure 2–2 shows the area 200 schematic.
Figure 2–2. Area 200 Schematic—Dual Device, SOIC (14 pin)
B2/SD
C206 C207
C209 C210
V2+
V2–
V2+
GND2
V2–
Power Supply Bypass
+
–
14
1
4
3
2
V2+
V2–
R212
C215
R216
C211
R221
R220
R218
R219
R217
R215
C212
C213
A2OUT
1/2 Dual Op Amp
A201–
A202–
A203+
A204+
+
–
R206
C202
R207
C203
R204
R203
R205
R201
R202
R209
C204
C201
B2OUT
1/2 Dual Op Amp
B201–
B202–
B203+
B204+
U201a
U201b
13
11
12
C214
R214
A2 FLT
C205
R208
B2 FLT
A2/SD
6
9
R211
U202
R213
Voltage Reference
V2+ VREF2
R210
C208