Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Names
NOTE: The HTML language reserves certain characters for specific functions (see Special Characters on page 109).
Write global preset name
EX(
,
X1!
NG
}
Nmg
X(
,
X1!]
Example:
E
1,Security 1NG
}
Nmg01,Security 1
]
Name global preset 1 “Security 1”.
Read global preset name
EX(
NG
} X1!]
Example:
E
2NG
}
Security 2
]
Write room preset name
EX1)
*
X(
,
X1!
NP
}
Nmp
X1)
*
X(
,
X1!]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room 1, preset 3 “Podium_
DVD
”.
Read room preset name
EX1)
,
X(
NP
}
X1!]
NOTES:
• Do not use leading spaces in preset names.
• If a preset is unassigned, the
X1!
displays [unassigned].
• If a global preset is saved, but not yet named, the default name is Preset
X(
.
• If a room preset is saved, but not yet named, the default name is Rm
X1)
Prst
X(
.
Write input name
EX!
,
X1!
NI
}
Nmi
X$
,
X1!]
Example:
E
1,Podium camNI
}
Nmi01,Podium cam
]
Name input 1 “Podium cam”.
Read input name
EX$
NI
} X1!]
Write output name
EX@
,
X1!
NO
}
Nmo
X@
,
X1!]
Example:
E
1,Main PJ1NO
}
Nmo01,Main PJ1
]
Name output 1 “Main PJ1”.
Read output name
EX@
NO
} X1!]
Front panel locks
NOTE: See Setting the Front Panel Locks (Executive Modes) on page 75 for more information on the Lock modes.
Lock all front panel functions
1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions
2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions
0X
Exe0
]
Enable Lock mode 0.
View lock status
X
X#]
NOTE: X! = Input number (for tie) 00 – (maximum number of inputs for your model) (00 = untied)
X@ = Output number 01 – (maximum number of outputs for your model)
X# = Lock mode 0 = mode 0 1 = mode 1 2 = mode 2
X( = Global or room preset number 00 - 32, 10 maximum for a room preset (00 = current configuration for view only)
X1) = Room number (for room presets) 10 max. (Each can have up to 10 presets (X(s) assigned.)
X1! = Name 12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.
CrossPoint and MAV Series Matrix Switchers • Programming Guide 103