The radio buttons and check boxes associated with each address field permit the
administrator to specify specific e-mail requirements for each recipient.
Edit these fields and controls as follows:
1. Click in the desired E-mail Addressee field. The graphic cursor becomes a text cursor.
2. Edit the e-mail address as desired. Standard e-mail address conventions
(for example: nnnnn@xxx.com) apply.
3. Press the <Tab> key on the keyboard or click in another field to exit the e-mail
addressee field.
4. In the square associated with each addressee, select one or more options about which
the addressee is to be e-mailed: missing input(s), fans, and power supply. In the floating
box that contains the input numbers, select the inputs to be monitored.
5. In the round radio buttons associated with each addressee, select whether the
addressee is to be e-mailed of failures, fixes, both, or not be notified.
The None radio button is useful for temporarily removing personnel from the e-mail list
when they are unavailable, such as on travel or vacation.
6. If desired, click the Send test E-mail button to test the e-mail function.
7. Click the Take button to make the e-mail address changes take affect.
Updating the Firmware
The firmware upgrade utility provides a way to replace the firmware that is coded on the
control board of the switcher without taking the switcher out of service.
NOTE: Upgrading the firmware does not overwrite the current configuration or
presets.
Update the switcher firmware as follows:
1. Perform steps 1 through 5 of Installing the Software, on page 111, to download the
firmware upgrade from the Extron website, www.extron.com.
2. Click Run in the File Download and Security Warning dialog boxes (see figure 68 on
the next page). The PC downloads the firmware update from the Extron website and
starts the Extron Installation Program to extract the firmware file.
3. Click Next. The program extracts the firmware files and places them in a folder
identified in the InstallShield Wizard window.
NOTES:
• Note the folder to which the firmware file is saved. When downloaded
from the Extron website, the firmware is placed in a subfolder of:
• Windows 7 or Windows 8: C:\Program Files (x86)\Extron\Firmware.
• Older versions: C:\Program Files\Extron\Firmware.
• The original factory-installed firmware is permanently available on the matrix
switcher. If the attempted firmware upload fails, the switcher reverts to the
factory-installed firmware.
4. Click Finish to exit the program.
CrossPoint and MAV Series Matrix Switchers • Matrix Software 119