3. Change a value: Press and release the button that relates to the desired value.
C O N T R O L
PRESET
ENTER
I / O
RGBHV AUDIO
ESC VIEW
Press and release the button(s) to configure the port as
follows:
Baud rate:
Enter — 9600 Preset — 19200
View — 38400 Esc — 115200
Serial protocol:
RGBHV or Video — RS-232 Audio — RS-422/RS-485
The selected buttons blink and the others remain lit.
In this example, the port is set to RS-422 at 38400 baud.
4. Exit the Serial Port Selection and Configuration mode: Press and release an
output button.
C O N T R O L
PRESET
ENTER
I / O
RGBHV AUDIO
ESCVIEW
5
All Control and I/O buttons return to unlit or background illumination.
Press and release an
input or output button.
Rear Panel Reset Operations
The rear panel has a Reset button that initiates various levels of resets,
dependant on the switcher model and defined in the table below:
Switcher model or
MAV Plus switcher matrix size
Reset
LED
Resets
All CrossPoint Ultra
MAV Plus 88, 128, 816, 164,
168, 1212, 1616, 248, and 328
Yes
Comparable to IPL
modes 3, 4, and 5
Hard reset (IPL mode 1)
All CrossPoint 450 Plus
MAV Plus 2412, 2424, 3216,
and 3232
No
Whole switcher reset
Absolute reset
Hard reset
For different reset levels, press and hold the button while the switcher is running or press
and hold the button while you apply power to the switcher. The Reset button is recessed, so
use an Extron Tweeker, a pointed stylus, or a ballpoint pen to access it.
CrossPoint and MAV Series Matrix Switchers • Operation 78