A SERVICE OF

logo

EQQE059W EQQE066E
EQQE059W THE FOLLOWING USER DEFINED EVENT RECORD CANNOT BE USED BECAUSE WORK
STATION
WSNAME
IS NOT AN AUTOMATICALLY REPORTING WORK STATION:
EXITREC
Explanation: An invalid user-defined event record has been found on the Event Manager’s work queue.
Workstations referenced by user-defined event records must be automatically reporting workstations. The current
workstation does not have this attribute.
System action: The incorrect event record is returned to the Event Manager’s free queue without any further
processing.
System programmer response: Determine if the user program generating the event should reference some other
workstation or if the attributes of the current workstation should be changed.
EQQE061E THE INPUT DATA SET, DDNAME = SYSIN, COULD NOT BE OPENED
Explanation: The EQQEVPGM program could not open the dataset referenced by the SYSIN DD statement, the
statement was not defined correctly, or no SYSIN DD statement was present.
System action: The EQQEVPGM program ends.
User response: Check that the SYSIN DD statement is present and that it is correctly coded. After making
corrections, resubmit the EQQEVPGM batch job.
EQQE062E EQQEVPGM INITIALIZATION FAILED
Explanation: The EQQEVPGM program found one or more errors during initialization.
System action: The EQQEVPGM program ends.
User response: Review the message log dataset for error messages. Remove the cause of each error and
resubmit the EQQEVPGM batch job.
EQQE063I EQQEVPGM ENDED NORMALLY
Explanation: The EQQEVPGM program has finished processing. No errors were found during execution.
System action: The EQQEVPGM program ends.
User response: None.
EQQE064E EQQEVPGM TERMINATED BECAUSE OF UNRECOVERABLE ERRORS
Explanation: A severe error occurred during execution of the EQQEVPGM program.
System action: The EQQEVPGM program ends.
User response: Review the message log dataset and the SYSUDUMP dataset to determine the cause of the error.
After making corrections, resubmit the EQQEVPGM batch job. If you cannot determine the cause of the error and if
the error persists, contact your IBM representative.
EQQE065I THE EQQEVPGM PROGRAM HAS STARTED
Explanation: The EQQEVPGM program has been correctly initialized and is about to start generating events.
System action: EQQEVPGM processing continues normally.
User response: None.
EQQE066E
SUBSYS
IS NOT A VALID SUBSYSTEM NAME. NO EVENT IS CREATED
Explanation: The SUBSYS keyword contains an invalid subsystem name.
System action: The event will not be created. The EQQEVPGM program continues processing the next event
creation statement.
User response: If the event should be created, make the necessary corrections and resubmit the EQQEVPGM
batch job.
92 TME 10 OPC Messages and Codes