EQQX503E EQQX604E
EQQX503E INVALID DBCS-CHARACTER(S) IN
GRPDEF
Explanation: The group definition ID field contains out-of-range DBCS characters. With the exception of DBCS
blank, X'4040', each byte must be in the range X'41' to X'FE'.
System action: The data is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the failing record and the position of the error.
User response: Specify a valid group definition ID. If the error occurred in batch, resubmit the job. If you cannot
find the reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause of the error, contact your IBM representative.
EQQX504E ODD NUMBER OF BYTES IN
GRPDEF
Explanation: The group definition ID field is specified as a double-byte-character-set (DBCS) field, and requires two
bytes per character. That is, the number of bytes must be a multiple of two.
System action: The data is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the failing record and the position of the error.
User response: Specify a valid group definition ID. If the error occurred in batch, resubmit the job. If you cannot
find the reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause of the error, contact your IBM representative.
EQQX505E NO ID SPECIFIED FOR DBCS GROUP DEFINITION
Explanation: The group definition ID field contains shift-out and shift-in DBCS characters, but you have not specified
a valid value for the group definition.
System action: The data is rejected.
Problem determination: Look in the diagnostic file (with ddname EQQDUMP) for further information. This file
contains a copy of the failing record and the position of the error.
User response: Specify a valid group definition ID. If the error occurred in batch, resubmit the job. If you cannot
find the reason for the error, contact your system programmer.
System programmer response: Review the TME 10 OPC message log to determine the cause of the error. If you
cannot determine the cause of the error, contact your IBM representative.
EQQX604E SELECT ONE OF THE LU NAME LINES
Explanation: There must be at least one entry in the subsystem name table and exactly one row must be selected
by a / in the first column.
System action: The system waits for you to respond.
User response: If you are logged on to TSO on the MVS where the TME 10 OPC Controller is running, select the
row with the Controller subsystem name and no Server LU name. If you are logged on to TSO on another MVS,
select a row with a LU name specified, thereby selecting the proper Controller subsystem and the LU name of the
Server handling the communication to the Controller.
Chapter 31. EQQXnnn Messages 381