
EQQW070I EQQW074E
EQQW070I THE EW CANNOT REPOSITION AT RESTART POSITION:
CYC
REC
Explanation: An event writer is started in event reader mode (with an EWSEQNO). The event writer cannot position
on the event dataset with the event dataset position that it has received. The restart position was probably overwritten
when the event dataset wrapped around.
System action: The event writer continues processing as normal.
TME 10 OPC administrator response: The event dataset may be too small. Make sure it is large enough to hold
all the events generated while the connection between the controller and the tracker with the started event writer is
down.
EQQW071I UNKNOWN RECORD TYPE SKIPPED BECAUSE IT IS TOO OLD
Explanation: The event writer encountered an unknown record type when skipping records of the submit/release
dataset that are too old.
System action: The record is skipped.
User response: None.
EQQW072E EVENT WRITER SEQUENCE NUMBER, EWSEQNO, MUST BE 1 TO 16
Explanation: An invalid sequence number was found in the EWSEQNO keyword of an event writer initialization
statement.
System action: TME 10 OPC initialization is terminated.
System programmer response: Change the sequence number to a number from 1 to 16 that is not already used by
an event reader subtask in the same address space.
EQQW073E IT IS NOT VALID TO START AN EVENT WRITER IN EVENT READER MODE WITH THIS TYPE OF
HOST CONNECTION
Explanation: The TME 10 OPC configuration does not support starting an event writer in event reader mode. When
the event writer is started with the EWSEQNO, it will try to pass events directly to the controller. EWSEQNO can only
be used in these circumstances:
The event writer is started in the same address space as the controller.
XCF connections. The event writer is started at a tracker system connected to the controller using XCF
communication links.
SNA connections.. The event writer is started at a tracker system connected to the controller using VTAM.
System action: Event writer initialization terminates.
System programmer response: Remove the EWSEQNO keyword from the EWTROPTS initialization statement.
EQQW074E THE SUBMIT/RELEASE DATA SET WITH DDNAME =
DDNAME
IS TOO SMALL
Explanation: The submit/release dataset must be large enough to contain 100 records.
System action: The workstation analyzer processing stops. Message EQQW502E is issued.
Problem determination: None.
System programmer response: Stop TME 10 OPC. Allocate a larger submit/release dataset. Start TME 10 OPC
again.
Chapter 30. EQQWnnn Messages 307