A SERVICE OF

logo

4-13
ISM 824 Integration Scaling Multiswitcher • SIS
Programming and Control
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to switcher)
URL Encoded (Web)
(host to switcher)
Response
(switcher to host)
Additional description
Query firmware version Q/q
Q/q
Ver01*x.xx
]
View the rmware version.
View internal temperature 7S 7S
Sts7
X1@]
Internal temperature in
degrees Fahrenheit.
Digital sync validation
processing (DVSP)
X! LS X! LS X4*,X4*]
Listed as horizontal and
vertical frequencies.
View input video standard
38 *
X!# 21 %2A X! # Ist X!* X1!]
View setting.
With verbose 2/3 not activated
GGeneral information
I/i I/i
X\•X\•X\•X\
•X\•X\•X\•X\]
Query the configuration of all
outputs (listed 1-8).
Query part number N/n N/n 60-787-01]
View the part number (based
unit).
Query part number for slots *N/n *N/n
60-787-01.
X\
X\ X\ X\]
View the part number (slot
population from slot 1-4).
Where:
:X\ = Output (card) type
A = Universal scaler D =Dual-output wideband
B = Video-only scaler E = Scan converter
C = Single-output wideband
X = No output present
Z = Internal wideband output (outputs 1 and 2)
Query firmware version
Q/q Q/q
x.xxx
]
View the rmware version.
View internal temperature 7S 7S
Sts 7
X1(]
Internal temperature in degrees
Fahrenheit.
View input video standard
38 *
X!# 38 %2A X! # X1!]
View setting.
OOthers:
Front panel lockout (executive mode)
Enable lockout 1X 1X
Exe1
]
Lock front panel (admin).
Enable Admin lockout 2X 2X
Exe2
]
Lock front panel (complete).
Disable lockout 0X 0X
Exe0
]
Unlock front panel.
View lockout status X X
x!
]
Show executive mode status
x! = 0 (off), 1 (view only),
or 2 (I/O ties only).