Sync termination switches—TheRGB(CrossPoint)matrixswitchershave
inputSyncterminationswitchesontherearpanel(gure2-16)thatprovidea
waytoconditionnon-TTLsynclevelsgreaterthan5Vp-p.Synctermination
enables the sync to be properly passed from input to selected output(s).
The matrix switchers have two sets of sync termination switches; one for
horizontal or combined sync and a second set for vertical sync.
The CrossPoint 450 PlusmatrixswitchershaveSyncterminationswitchesfor
inputs1through8.
The CrossPoint UltramatrixswitchershaveSyncterminationswitchesfor
inputs1through4.
CrossPoint Ultra
816, 168, 1212, and 1616
CrossPoint Ultra
84, 88, 124, and 128
H SYNC V SYNC
V
V
15
16
15
16
1
4
2 3
1
4
2 3
OUTPUTS OUTPUTS
INPUTS INPUTS
SYNC
V SYNC
H
HV
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
CrossPoint 450 Plus
2412, 2424, 3216, and 3232
Figure 2-16 — Sync termination switches
Eachswitchprovidestheoptionofselectingeither510ohmsor75ohms.
The 75 ohms position is required only for an input with non-TTL sync, greater
than5Vp-p.Thenormalpositionis510ohms.
N
An input that produces an out of sync display, a display that is rolling vertically
and/or tearing horizontally, could indicate a non-TTL sync input.
A device that is known to output non-TTL sync levels (greater than 5V p-p)
should be connected to one of the inputs with sync termination switches, and the
switches for that input should be set to the 75 ohm position. If you are not sure,
check the specifications in the user’s manual for the input device.