Installation
3-7
Part 1061253B
E 2006 Nordson Corporation
Input Connector TB2
Refer to Table 3-5 and Figure 3-4.
The inputs from the TB2 input connecter (3) are
designed for contact closure or an open collector
output. With the exception of the 4-20 ma remote
analog input, the input terminal voltage is 24 Vdc
and will source about 8 ma.
Table 3-5 Input Connector TB2 Pin Assignments
Pin Function Remote Local Description
1 Common
X X If this input is not interfaced to external
equipment, a jumper must be installed.
O
enin
this in
ut shuts down the
ower
2 Machine Stop
Opening this input shuts down the power
supply unit, sets the FAULT output, and
causes the F STOP fault message to appear
on the display.
3 Common
X NA Remotely controls the power supply unit when
operating in the Remote mode. A pulse or
momentar
contact closure to this in
ut
4 Remote Standby
momentary contact closure to this input
places the power supply unit in the Standby
mode. (The Off/Reset contact must be
closed.)
5 Common
X NA Remotely controls the power supply unit when
operating in the Remote mode. This contact
must be closed for the lamphead to be turned
6 Remote Off/Reset
must
e
c
ose
or
t
e
amp
ea
to
e
turne
on. Opening the contact will turn the
lamphead off and will clear a fault condition.
7 Common
X NA Remotely controls the power supply unit when
operating in the Remote mode. A pulse or
momentary contact closure to this input turns
the CoolWave lamphead to the on state (The
8 Remote Lamp On
t
e
oo
ave
amp
ea
to
t
e
on
state.
e
Off/Reset contact must be closed). The
Off/Reset contact must be opened to turn the
lamphead off.
9 Common
X X If this input is not interfaced to external
equipment, a jumper must be installed.
O
enin
this in
ut shuts down the
ower
10 External Interlock
Opening this input shuts down the power
supply unit, sets the FAULT output, and
causes the F LOCK fault message to appear
on the display.
11 Chassis Ground X X Not Used
12 4-20 ma input
or
0-10 Vdc
X NA Remotely varies the lamphead output power
when the unit is in the Remote mode. The
lamphead power has three setpoints:
Lo (35%) = 0-3 Vdc or 4-7.5 ma
Med (65%) = 4-5.5 Vdc or 11-14 ma
Hi (100%) = 6.5-10Vdc or 17-20 ma
13 4-20 ma input
or
0-10 Vdc
(ground)
NOTE: If this input is used to vary the
lamphead power and the current drops below
about 3 ma, the lamphead power becomes the
SETPOINT power. If remote variable power is
not required, leave these terminals
disconnected. Reversing the ground and
signal wires can cause erratic system
operation.