Installation
3-8
Part 1061253B
E 2006 Nordson Corporation
Remote Power Level Control
The 4-20 ma power level control can be modified to a 0-10 Vdc power level control if required. Contact
your Nordson UV curing representative for more information on this conversion.
Lamp Start-Up Timing Diagram for
Remote Input Contact Closures
See Figure 3-5. The Off/Reset contact must be closed for the unit to go to Standby or On. Once the
lamphead is put into the Standby or On mode the lamphead will remain in that mode until the Off/Reset
contact is opened.
1500003A
Lamp Off Lamp to Standby Lamp to ON Lamp Off
1
0
1
0
1
0
LAMP ON
STANDBY
OFF/RESET
>100 ms pulse
10 seconds to warm up
8 seconds to stabilize
>100 ms pulse
Figure 3-5 Lamp Start Up Timing Diagram for Remote Input Contact Closures
Rapid Startup
Use if your system will sit idle in the Standby mode
before moving to the On mode.
1. On the LAMP selector of the host machine (or
master control unit’s lamp selector), press the
Standby button. There will be an approximate
10 second warm-up time for the magnetron
filament.
2. After the 10 seconds the system will go into
standby and remain there indefintely.
NOTE: Do not leave the power supply in the
standby mode for longer than 30 minutes.
Prolonged standby periods will shorten the
magnetron life.
3. Press the On button to enable the UV light.
The light will turn on instantly but will take
approximately 8 seconds to stabilize. After the
8 seconds, the system ready output contact
(TB1) will close.
Standard Startup
Use to go directly through the warm-up to the On
mode.
1. On the LAMP selector of the host machine (or
master control unit’s LAMP selector), press the
LAMP On button.
2. During the next 10 seconds the unit will go
through the warm up cycle before turning to On.
3. After approximately 8 more seconds the unit
has stabilized and the system is ready to run.
The system ready output contact (TB1) will
close.