Operation
4-2
Part 1061253B
E 2006 Nordson Corporation
Display and Controls (contd)
Table 4-1 Displays and Controls
Item Control Description
1 Main Power Switch Turns the main power on and off to the CoolWave system.
2 POWER SETTING
Lo = 35%
Med= 65%
Hi= 100%
The system is factory set to operate at 100% output. To check
the power level, press the Set/Save button. Change the
output by pressing the up or down arrow buttons. Changes
take place as soon as you press the up or down arrow button.
Press the Set/Save button in order to save these changes. If
the Set/Save button is not pressed the power will revert back
to the last saved level when the main power is cycled.
3 DISPLAY CURRENT Displays the current flowing to a magnetron. Press the button
next to the appropriate magnetron to display that magnetron’s
current. To leave this display press the same button again.
4 LAMP Off: Turns the lamphead off.
Standby: Applies warm-up power to the magnetron filament
and the message WARMUP appears in the display while
warming up. Once it is warm, STDBY appears.
On: Turns the lamphead on after magnetron filament is warm
and LMPDLY is displayed and then LAMPON.
5 NETWORK Sets system operation from the Local or front panel mode to a
Remote or external device or controller.
6 Digital Display Displays power levels, operation and fault messages.